Sidewall sprinkler head. Tyco TY-FRB 5. 0 (115) Pendent cULus FM(2) 250 (17. K Factor. 3 m) from the sprinkler shall be in conformity with Table 4-9. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VKKW), and is VdS Approved. Protection in commercial buildings in case of fire or smoke. K Factor: 3. Sidewall fire sprinkler heads are used when there isn’t space for water pipes in the ceiling, and they spray water in a crescent shape. Points $11. 6 N-m of torque. Add to The Micromatic® Viking Standard Response Horizontal Sidewall Sprinkler VK104 is cULus Listed for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Their half-deflector allows them to dispense water in a half-circle shape for greater coverage in such a small space. Sidewall sprinkler heads are perfect for closets or narrow storage spaces without overhead pipe access. 0 K-FACTOR,3/4" NPT** GENERAL DESCRIPTION The 8. Select from our full lineup of quality extended coverage fire sprinklers to find the Horizontal Sidewall : Response : Quick & Standard : Series TY-FRL Extended Coverage Sprinkler. The VK486 Residential Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK486 is cULus Listed with a flow rate of 13 gpm (49. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). E: info@shieldglobal. They’re also ideal for rooms Page 1 2-01 CENTRAL Model A 2. They are also often used on upper floors to avoid placing water-filled pipes in freezing attics. 8 (40), 4. 4 million Omega brand fire sprinklers manufactured since 1982 by Central Sprinkler Corp. 2 (60), 5. • Other Options: A sidewall is allowed to be located further G6-56 Series HSW QR Concealed Sidewall Sprinklers; G6-56 Series HSW QR Concealed Sidewall Sprinklers. 01725A (available since 1971) Viking Technical Data may be found on Sprinkler Cabinets: A. 4K Horizontal Sidewall Sprinkler Head in White. They are “extended coverage spray Sidewall Sprinkler Heads. Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The manufacturer part number is 57-578-4-286 and the Sprinkler Please use the options below to filter our Sprinklers Catalog. 6 (109) CAD Drawings Engineering Specs BIM Files Translations Bulletin 135; French / français; sidewall sprinklers teCHniCal data December 12, 2013 the Viking Corporation, 210 n industrial park drive, Hastings Mi 49058 sprinkler Cabinets: A. K Factor: 8. 4 out of 5 Customer Rating. Cover plates available. NPT Sprinkler Head Adapter Tee (P/N 80249) For dry pipe system installations, use only the side outlet of maximum 2 1/2 in reducing tee when locating Series DS-3 Dry-Type Sprinklers directly below the branch line Otherwise, use the configuration shown in Figure 6 to assure complete water drainage from above Series DS-3 Dry-Type Sprinklers and Viking Horizontal Sidewall Fire Sprinkler Freedom (VK484) Sprinkler Head Listings and Approvals. NPT threads. 05 m) perpendicular to the slope. 0 (115) CAD Drawings Engineering Specs Bulletin 047? Learn about the submittal builder. com, please use one of the 11. Additionally, it has a temperature rating of 165°F (74°C) With sprinklers, control panels, and cover plates, Tyco® offers everything needed to protect residential spaces without giving up on aesthetic quality. Sprinklers, Nozzles & Accessories. รายละเอียดย่อ : TYCO TY-FRB, TY3332, 5. Products and Solutions Back. 12 5. The pendent and upright models can be used in all hazard The VK460 Residential Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK460 is a small, thermosensitive, glass bulb Sprinkler VK490 is provided with a pipe guide to properly locate the sprinkler and allow the 1/4” adjustment of the cover plate. Update Package english spanish-latin-america Software. The options may be chosen on the product sidewall sprinklers teCHniCal data December 12, 2013 the Viking Corporation, 210 n industrial park drive, Hastings Mi 49058 sprinkler Cabinets: A. Cara kerja sidewall sprinkler head adalah memiliki deflector yang Viking is a proud world leader in the design and manufacturing of life-saving fire sprinklers. 0 (115) Engineering Specs Bulletin 015? Learn about Tyco TY-B (TY3351) Horizontal Sidewall Sprinkler Head Overview . V A Complete Line of Sidewall Sprinklers Model G Vertical Sidewall-Upright. 5 s. Bulletin 208. 6 K-Factor, and is rated for Reliable standard response sprinklers are ideal for protecting ordinary and extra hazard applications such as parking garages, restaurant service areas, manufacturing facilities, and mills to control the spread of fire. 3 m) to light fixtures or similar obstructions. Rohini Sector 5, New Delhi 805, Crown Heights, Hotel Crowne Plaza Complex Sector 10, Rohini Sector 5, New HORIZONTAL SIDEWALL SPRINKLERS MODEL FR-1 FAST RESPONSE QR-EC/EC, SOLDER TYPE, 8. This Tyco TY-FRB Grey Horizontal Sidewall Fire Sprinkler features a glass bulb activating at 286F (141C) with a 5. WARNING: Cancer and Reproductive Harm - www. Benefits. TY1334 1/2 in. of the sprinkler. Find out how they work, what they look like and when to use them in your building. 6 K-factor specific application window sprinklers (TY3388, TY3488), see TFP620 for technical information and listing details This Horizontal Sidewall sprinkler features a Brass finish and 135F (57C) activation temperature. (300 mm) from the wall. 2). (80lpm/bar ) Response Time Index (RTI) Standard 50 Quick Response 30 Nominal Thread Size ½”NPT(15mm) Orfice Size 13mm Max. The VK638 QREC Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK636 is designed specifically to protect corridors, hallways, decks, walkways and any other application where a wide spray pattern is optimal. 6) RD061 Horizontal Sidewall Quick Response Sprinkler, 15mm (½”), FM approved, cULus Listed, LPCB, VdS, CE View Full Details Sprinkler Wrench for 15mm & 20mm Heads The VK360 Quick Response Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. Horizontal sidewall sprinkler are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. KFR80 Series Sprinklers. 6K Dry, Horizontal Sidewall, Pendent and Quick Response Sprinkler Head in Chrome Plated 👏 $ 157. The Nickel-Chrome plate sprinklers are decorative & attractive so it is well matched to customer’s interior decoration. 5 bar Sidewall sprinkler heads: Sidewall sprinkler heads are mounted on walls and are typically used in areas with limited ceiling space, such as hallways and stairwells. 1 S. If you continue using IE, your experience will be degraded and you will not be able to check out. K Viking is a proud world leader in the design and manufacturing of life-saving fire sprinklers. 72P ©MEYERFIRE DECEMBER 2022 PUBLISHED 2022 | NEXT UPDATE COMING 2025 LAYOUT FOR STANDARD SPRAY SPRINKLERS SERIES BY MEYERFIRE UNIVERSITY | DECEMBER 2022 SUMMARY Sidewall sprinklers carry a unique few challenges compared to pendents and uprights: they can be (1) This Horizontal Sidewall sprinkler features a Chrome finish and 155F (68C) activation temperature. EACH This product was purchased before. Like upright sprinklers, sidewall fire sprinkler heads live up to their name. The minimum and maximum distances between the most common sprinkler heads, as well as the head-to-wall distance, are carefully observed with the NFPA 13. However, dry sprinkler heads, also called dry barrel sprinklers, have supporting and specific applications: Dry sprinkler heads must be used for pendent or sidewall orientations within dry systems unless conditions are met to prevent water from getting trapped and freezing in the pipes supplying them. Figure A) are automatic sprinklers of the “quick re-sponse” fusible solder type. View Product. The Victaulic FireLock Dry Sprinkler Sleeve and Skirt, Flush Plate, and Recessed Escutcheon Options - Installation Instructions I-40. Sprinkler Heads. This Reliable Model F1FR56 Horizontal Sidewall Fire Sprinkler is a quick response, standard coverage Horizontal Sidewall fire sprinkler head, activating at 155F (68C) with a 5. With your permission, we also set performance and functionality cookies, analytics cookies, advertising cookies and social media cookies. ). p65warnings. Select from our full lineup of quality extended coverage fire sprinklers to find the model that best suits your needs. All Viking Sprinkler Families. The room has a pendant sprinkler that is less than 6' away from where the sidewall sprinkler would be located. 6 K-Factor, and 1/2 in. 6 (80) Style List: Concealed Pendent, Horizontal Sidewall, Intermediate Level The VK360 Quick Response Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. . com no longer supports Internet Explorer. Viking Horizontal Sidewall Fire Sprinkler Freedom (VK486) Sprinkler Head Listings and Approvals. Model G Horizontal Sidewall-HSW1 Deflector. The spinkler can also be installed with two pieces of Recessed Escutcheon. F: +44 1708 347637 sidewall sprinklers teCHniCal data December 12, 2013 the Viking Corporation, 210 n industrial park drive, Hastings Mi 49058 sprinkler Cabinets: A. CODE-COMPLIANT CREATIVITY We had just this situation on a project a few weeks ago, and tried to think creatively to get a code-compliant solution that’s best for the owner, yet doesn’t However, dry sprinkler heads, also called dry barrel sprinklers, have supporting and specific applications: Dry sprinkler heads must be used for pendent or sidewall orientations within dry systems unless conditions are met to prevent water from getting trapped and freezing in the pipes supplying them. Quick View Part #GGL423115503 Item #2445381 Mfr. Consumer Product Safety Commission (CPSC) and Central Sprinkler announced today the nationwide recall of approximately 8. WORKING PRESSURE 175 psi (1200 kPa) 175 psi (1200 kPa) ESCUTCHEON Recessed Recessed GLOBE RE Sidewall Head Sprinkler ₹ 345/ Piece Get Latest Price. There are several options, sizes, shapes, and temperatures sensitivities within each type HD Horizontal Sidewall Sprinkler is a small, thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements. Sprinkler head obstruction distances on an opposite, adjacent, or the same wall as a sidewall sprinkler are slightly different. connection 1/2" npt/15 mm 3/4” npt/20 mm max. com 1. wide. If there is a sidewall on the opposite side, then this is measured to the midpoint between the FESCO Sprinklers are thermo-sensitive glass bulb sprinklers available in different finishes and temperature rating to meet design requirements. Data Sheet. For exposed piping sys-tems, the sprinkler should be oriented so the frame are parallel with the branch line pipe. 1. The Sprinkler Identification Number (SIN) is VK305. The sprinkler orifice design, with a K-Factor of 5. ESC Download. This animation shows the installation of a Viking's Residential Flat Plate Concealed Horizontal Sidewall Sprinkler, the Model VK480. Response. The VK360 Quick Response Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to FireLock™ Series FL-SR Sprinklers: Upright: V2861, V4261, V2703, V3401 | Pendent and Recessed Pendent: V2851, V4251, V2707, V3405 F1Res Series Residential Sprinklers. We use cookies to give you the best experience when using our website. Revit Downloads Revit US/GLOBAL - 45. Sprinklers must be installed after the piping is in place, to prevent mechanical damage. Twelve-head capacity: Part No. Tyco TY-B (TY3351) Horizontal Sidewall Fire Sprinkler Replacement Products > Nozzle and Monitor > Fire Sprinkler System > Sprinkler Heads > TYCO datasheet_tyco_tyfrb_ty3332-ty4332_sidewall_spk. 6 Data Sheet. 5 L/min) for a 16 x 16 ft. Use the links below to learn more about our products. Bulletin 050. They may also be installed Tyco TY-B (TY3351) Horizontal Sidewall Sprinkler Head Overview . In short, an overhang that’s just beyond the reach of a dry sidewall sprinkler can take us to a whole new cost tier in the design of a sprinkler system. Style List: Conical Concealed Horizontal Sidewall (CCP) K Factor: 8. 0 (115) CAD Drawings Engineering Specs Bulletin 055 ? Learn about the submittal builder. X Points Call for Pricing Call for Pricing. 0 (43), 4. RASCOFLEX® Sprinkler Connections – Americas. G6-80 HSW QREC Concealed Sidewall Sprinklers; G6-80 HSW QREC Concealed Sidewall Sprinklers. Maximum Temperature: 155 Select Maximum Temperature Package Quantity Info: Each: 1 Inner Pack: 1 Model F1FR80 QREC Sidewall Sprinkler Summary Sprinkler Model K-Factor gpm/psi1/2 Max. The VK605 Microfast® EC/QREC Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK605 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. Filter Results Close. Sidewall sprinkler adalah jenis head sprinkler yang dipasang di dinding dan dirancang untuk menyemburkan air ke samping dan kemudian menyebar secara horizontal. The distance between light fixtures or similar obstructions located more than 8 ft (2. Sprinkle Type. 4 states that sidewall heads cannot Residential Sidewall Sprinkler Head - White finish - White cover plate ESFR Sprinkler Head - Brass finish . 6 m), a maximum spacing of 12'-6" (3. Orientation : Horizontal, Sidewall : Response : Standard, Quick The VK306 Microfast® Quick Response Vertical Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK306 is a small thermosensitive glass bulb spray sprinkler designed for installation in either the upright or pendent position. 1 BAR) UL, FM and connects to wet piping systems. In SPRINKLER V28 V42 V27 V34 Horizontal Sidewall AVAILABLE WRENCHES Sprinkler V56-2 Recessed V56 Open End V27-2 Recessed V27 Open End V34-2 Recessed V34 Open End 3/16 Hex-Bit V2826 and V4226 V2710 V3410 Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Min. Model G Vertical Sidewall-Pendent. Brass. 4 | 6. 1 SI. Fire Sprinkler Head, RASCO/Reliable Model G Recessed, R1011 R1013 R1015 R1016, Pendent, Standard Response, 1/2" NPT - Available In Multiple Configurations Standard Response, Standard Spray, Pendent, 1/2 inch NPT, Fusible Link. Style List: Horizontal Sidewall. 01725A (available since 1971) Viking MicrofastHP® Quick Response Horizontal High Pressure Sidewall Sprinkler VK319 is . Six-head capacity: Part No. The measures include using “return bend FIRE SPRINKLER SPACING. working pressure 175 psi (1200 kpa) 175 psi (1200 kpa) globe re-designation – – globe equivalent gl5628 gl8129 Sidewall sprinklers shall be permitted to be installed in the face of a soffit located directly over cabinets, without requiring additional sprinklers below the soffit or cabinets, where the soffit does not project horizontally more than 12 in. 0K model can cover 16'x24'. The silicone cover gasket is pre-assembled with the concealed cover for an acceptable sprinkler seal for use in a cleanroom or clean zone. Viking Freedom® Residential Concealed Horizontal Sidewall Sprinkler VK490 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on concealed pipe systems, where the appearance of a smooth wall is desired. Valves, Devices, & Components. Connection Type. XL Series Institutional Sprinklers. One sprinkler can cover an impressively large area. For more information regarding the proper handling, storage, and installation of Reliable fire sprinklers, please see Caution Sheet 310. 3. Ferguson. To deliver the design density, Sprinkler 4 must RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER (TY2334) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH. The sprinkler uses a push-on/pull-off flat cover plate assembly. This Reliable Model F1FR56 Horizontal Sidewall Fire Sprinkler is a quick response, standard coverage Horizontal Sidewall fire sprinkler head, activating at 135F (57C) with a 5. British Manufacturer & Supplier of Fire Sprinklers & Fire Suppression Equipment. 61 Select options This product has multiple variants. For easy access to the Viking families in Revit® use vDesign available here! This page last updated 10/04/2023 . The materials and finishes of heads Shield Fire, Safety & Security Ltd Unit 3, Endeavour Drive Basildon, Essex SS14 3WF. Standard Sprinkler Wrench. The special Polyester and Electroless Nickel PTFE Disclaimer Distribution Patterns: The distribution patterns are provided to illustrate the approximate water spray trajectories for various Reliable sprinklers at pressures of 7, 15 and 30 psi, unless otherwise noted. Info Requires Certification. Viking Freedom® Residential Horizontal Sidewall Sprinkler VK460 is a small, thermosensitive, glass-bulb residential sprinkler available in several different fin- Sprinkler Cabinets: A. Standard spray sidewall sprinklers are especially sensitive to obstructions. Use Teflon tape or soft thread sealant on male thread of the sprinkler for leak tight sprinkler joint. Reliable quick response sprinklers are available in a variety of finishes and temperatures, employing either a rugged fusible link or a frangible glass bulb operating element. Style List: EC Pendent, Horizontal Sidewall, Pendent. com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical 1/2 in. The 8. However, the sprinkler placement is more than square 360 gear drive white horizontal sidewall head 1/2" Brass sidewall type fire sprinkler tyco, 68 degree celsius, Ce approved side wall sprinkler; Victaulic brass horizontal sidewall sprinklers; Sainath fire stainless steel sidewall type sprinkler; Sd glass bulb sprinkler, for fire fighting, ceiling mounted; Bfs side wall fire sprinkler, 68 degree Horizontal Sidewall, Intermediate Level Upright, Pendent, Upright, Vertical Sidewall. Standard Response vs Quick SPRINKLER V28 V42 V27 V34 HORIZONAL SIDEWALL AVAILABLE WRENCHES SPRINKLER V56-2 Recessed V56 Open End V27-2 Recessed V27 Open End V34-2 Recessed V34 Open End 3/16 Hex-Bit V2870 and V4270 V2709 V3409 Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Min. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VKKW). The VK960 and VK962 Pendent Vertical Sidewall and Horizontal Sidewall are just two of thousands of industry-leading sprinklers available to customers! The VK960 and VK962 are quick response glass bulb, automatic sprinklers. 6 metric*), allows the sprinkler’s efficient use of available water supplies Fire Sprinkler Head, RASCO/Reliable Model G Recessed, R1011 R1013 R1015 R1016, Pendent, Standard Response, 1/2" NPT - Available In Multiple Configurations Standard Response, Standard Spray, Pendent, 1/2 inch NPT, Fusible Link. The deflector produces a discharge that looks somewhat like half of a normal sprinkler umbrella pattern. Browse all quick Step4. 6 imp. CAD Drawings Protect a larger area with your fire suppression system with extended coverage sprinklers. K Factor: 5. 6 m) parallel to the slope, and 10-ft (3. This Viking Microfast QR Sidewall Fire Sprinkler features a glass bulb activating at 155F (68C) with a 5. There are various types of fire sprinklers are grouped in blocks which make it easy to import these AutoCAD models into your CAD scene. , Inc. 75 Add to cart; Viking (FPP) Sprinkler Head Storage Box $ 21. All Viking Sprinkler Families - 2017 (opens in a EXTENDED COVERAGE QUICK RESPONSE RECESSED HORIZONTAL SIDEWALL SPRINKLERS SIN V2758 V3416 ORIENTATION HSW HSW K-FACTOR1 5. 7 to 19. 6 Imp. 6 states that there cannot be adjacent or opposite sidewall heads in the same room and 8. 1 BAR) and connects to wet piping systems. A leak-tight joint requires only 14. RFS42 60 (4. Each Freedom sidewall sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years. 0 Imp. The word ‘Top’ Depends on the listing of the sprinkler head, and how much water pressure you have available. 6 K-Factor, and is rated for Light and Ordinary Hazard occupancies MODEL: SD1125 The Model A SD1125 ½”orifice, extended coverage horizontal sidewall sprinkler is designed for extended coverage or recessed installation. 1 s. Additionally, it has a HEIGHT FOR SIDEWALL SPRINKLERS FX108. Victaulic FireLock™ Model V2740 The VK530 ELO Upright Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK530 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements. Each horizontal sidewall head features a brass frame and copper deflector. In this example, Sprinkler 4 is not in a small room and has to cover an area of 225 ft. New Only. 155F 5. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube Viking, White, Cover Plate For Residential Concealed Sidewall Fire Sprinkler Head $ 21. Crome. Obstructions projecting from the same wall as the one on which the sidewall sprinkler is installed shall be in accordance with NFPA 13, Table 8. The design incorporates state-of-the-art, heat responsive, frangible glass bulb design (quick Viking Quick Response Extended Coverage Horizontal Sidewall Sprinkler VK630 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. Sprinkler Spacing. 0 imp. 2) cULus 175 (12. 0 K-Factor (17/32 inch orifice), Model FR-1 QR-EC/EC Horizontal Sidewall Sprinklers (Ref. CODE-COMPLIANT CREATIVITY We had just this situation on a project a few weeks ago, and tried to think creatively to get a code-compliant solution that’s best for the owner, yet doesn’t spike the cost for a dry SPRINKLER HEAD Horizontal Sidewall Sprinkler Sprinkler Identification Number Standard SD1133 (bulb 5mm), Quick Response SD1121 (bulb 3mm) Style Horizontal Sidewall K Factor 5. Deflector . See full size image 5. 6gpm/psi ½. Comprehensive Solution One-stop-shop for all residential sprinkler system needs. /8. To deliver the design density, Sprinkler 4 must Residential Flat Concealed Horizontal Sidewall Sprinkler – RFS42 – Bulletin 048 Sprinkler K-Factor Temp Colour Part No. The manufacturer part number is 57-578-9-200 and the Sprinkler The VK104 Micromatic® Standard Response Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK104 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. For Horizontal Sidewall Sprinklers, use a standard wrench. CPSC alleges that Omegas are defective and could The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. 8, 4. 6 K-Factor, and is rated for Light and Ordinary Hazard occupancies K80 (K5. Part #GL423115503 3. The cover plate is attached to the skirt using 135°F (57°C) ordinary temperature classification solder. Horizontal Sidewall Sprinkler Installation The TYCO Series TY-B Recessed Hor - izontal Sidewall Sprinklers must be installed in accordance with The Micromatic® Viking Standard Response Horizontal Sidewall Sprinkler VK104 is cULus Listed for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. During installation be aware that over tightening will cause permanent damage to the 3/4 in. Concealed Sidewall Sprinkler Heads. The design incorporates state-of-the-art, heat responsive, frangible glass bulb design (quick Viking Horizontal Sidewall Fire Sprinkler Freedom (VK486) Sprinkler Head Listings and Approvals. Viking Microfast Quick Response Horizontal Sidewall (VK305) Fire Sprinkler Head. 5. Style List: Horizontal Sidewall, Pendent. /11. See full size image. However, it must be emphasized that Reliable sprinklers must be installed according to the pertinent National and Local Fire Codes, Standards and Installation Sidewall sprinklers are similar to standard sprinkler heads, with the exception of the deflector. White finish & 155F temperature w/ a 8. However, the sprinkler placement is more than square Standard response sprinkler systems are designed to suppress and limit the spread of fire by wetting the area surrounding a flame to remove a fire’s fuel source. 06. X Points Call for Pricing “Sidewall sprinklers shall be installed no closer than 8 ft (2. 6 and 4. The Micromatic® Viking Standard Response Horizontal Sidewall Sprinkler VK104 is cULus Listed for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. The latest Fire Service Act can protect more than 200 square feet with a single head in some environments. Reliable quick response sprinklers are ideal for protecting light and ordinary hazard applications such as office buildings, G6-56 Series HSW QR Concealed Sidewall Sprinklers. Crome Finish. This standard response sprinkler head has a maximum working pressure of 175 PSI (12. 7. 02 As their name suggests, sidewall sprinkler heads are installed so that they protrude horizontally from a wall. Are you looking for a fire protection system without compromising the aesthetics of your ceiling? The Tyco® TY-FRB sprinklers are designed to respond quickly in light and ordinary hazard The VK630 QREC Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK630 is a thermosensitive spray sprinkler available The VK481 Standard Spray Concealed Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK481 is cULus Listed (Quick Fire Sprinkler (Sidewall)68 degree celcius (red bulb)Standard Response1/2" (DN15) Fire Sprinkler Sidewall Sprinkler Head; Fire Sprinkler Sidewall Sprinkler Head. 8 (84), 7. Each sidewall head features a bronze frame and bronze deflector. The basic rule is that no sidewalls can be located within the maximum protection area of another sprinkler unless they are equipped with baffles, or there are special considerations regarding “kitchen cabinets, soffits, or other fixtures hang from the wall. 8K - Brass - 5513342470 GR03B R1011- 135 Degree - Listed below are all Revit® families currently available for Viking sprinklers, valves, and systems. Victaulic FL-QR/SW (V3410) 8. 1 BAR) and connects to wet pipe fire protection systems. Side Wall. Step 1. This Tyco Model TY-L Horizontal Sidewall Fire Sprinkler is a standard response, standard coverage sprinkler, activating at 165°F (73°C) with a 5. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used Viking is a proud world leader in the design and manufacturing of life-saving fire sprinklers. Additionally, as with all slopes, the sprinkler F1-56 Series Standard Response Sprinklers; F1-56 Series Standard Response Sprinklers. See more The VK305 Microfast® Quick Response Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK305 is a small thermosensitive Learn about the features, benefits and specifications of Tyco® Model SW-20 and SW-24 horizontal sidewall sprinklers for ordinary hazard occupancies. Series TY-FRB Horizontal and Vertical Sidewall Sprinkler Installation The Series TY-FRB Horizontal and Vertical Sidewall Sprinklers must be Pendent sprinkler heads are mounted vertically, pointing down from the ceiling, so that when activated, the deflector plate allows water dispersion down and to the sides; Horizontal or Sidewall heads are wall-mounted and when activated, will deflect the stream of water forward, down and to the sides (but not up). Pendent. 6 (80), 8. 6 & 8. Refer to the Each TY-FRB sprinkler is made by Tyco, a global leader in fire-suppression products. ” Each TY-FRB sprinkler is made by Tyco, a global leader in fire-suppression products. Concealed sprinkler heads : Concealed sprinkler heads are hidden inside the ceiling or walls and are installed most often in areas where aesthetics are a concern, such as hotels and museums. 1 BAR) FM, and is UL Listed for 250 PSI (17. DESCRIPTION. Working Pressure 175PSI(1200kPa) glass bulb sprinkler if the bulb is cracked or if there is a loss of liquid from the bulb. Tyco TY-B (TY3351) Horizontal Sidewall Sprinkler Head Overview . 6 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard), 1/2"NPT, UL Listed, FM approved, USA This sidewall sprinkler head has a maximum working pressure of 175 PSI (12. Fire protection sprinkler system for metal buildings US6889774B2 (en) 2002-02-27 Tyco TY-B (TY3351) Horizontal Sidewall Sprinkler Head Overview . 0 K-factor Standard Response Standard Coverage Upright & Pendent Pendent Fusible Solder Type Automatic Sprinkler Tyco Fire Products --- www. 2 | 6. Quick response with Extended coverage; Horizontal Sidewall ment of the sprinkler. 0) FM R4842 Horizontal Sidewall R4862 Table A Important! Reliable fire sprinklers must Viking Cleanroom Cover Assemblies are low-profile covers intended for use in cleanroom environments with Viking Mirage® Quick Response Concealed Pendent Sprinkler VK462 (opens in a new window) and MRI Sprinkler VK462. Do not attempt to make-up for insufficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Show advanced filters Hide advanced filters. 4. VIEW. This Tyco TY-FRB White Horizontal Sidewall Fire Sprinkler features a glass bulb activating at 286F (141C) with a 5. They are mounted onto the walls or onto beams in tighter spaces such as hallways and closets. FireLock™ Series FL-QR Sprinklers: Upright: V2815, V4215, V2704, V3402 | Pendent and Recessed Pendent: V2801, V4201, V2708, V3406 The VK426 and VK427 Flush Pendent and Flush Horizontal Sidewall Institutional Sprinklers are just two of thousands of industry-leading sprinklers available to customers! The VK426 and VK427 are small, flush, solder link and lever sprinklers made with tamper-resistant construction. Free AutoCad drawings of a fire sprinkler. Buy online at QRFS. Sprinkler Wrench for 15mm & 20mm Heads. Installed on one wall of a room, a sidewall head will distribute, or throw, this pattern across the length of the room, covering the entire square footage of the room. 7 out of 5 Customer Rating. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation I am trying to install a sidewall sprinkler head with a coverage area of 14' x 14'. and its subsidiary, Central Sprinkler Co. 9 (71), 5. The measures include using “return bend Tyco TY-B (TY3351) Horizontal Sidewall Sprinkler Head Overview . TFP151_PT Technical Data Sheet – Portuguese Translation (Portuguese-Brazil) TY-B Sprinklers - TFP151 (Portuguese) Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Horizontal sidewall sprinkler are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. centralsprinkler. This Tyco TY-FRB Chrome Horizontal Sidewall Fire Sprinkler features a glass bulb activating at 286F (141C) with a 5. pdf. 2K Horizontal Sidewall and Standard Response Sprinkler Head in White Fast # Part # T510734200; Item # 1959079; Manufacturer Part #51-073-4-200 4. SPRINKLER V28 V42 V27 V34 Horizontal Sidewall AVAILABLE WRENCHES Sprinkler V56-2 Recessed V56 Open End V27-2 Recessed V27 Open End V34-2 Recessed V34 Open End 3/16 Hex-Bit V2826 and V4226 V2710 V3410 Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Min. For easy access to the Viking families in Revit® use vDesign available here! This page last Sidewall, extended coverage, and residential sprinklers do not apply. Rapid Response Premier Contractor Access Find a premier partner installation Disclaimer Distribution Patterns: The distribution patterns are provided to illustrate the approximate water spray trajectories for various Reliable sprinklers at pressures of 7, 15 and 30 psi, unless otherwise noted. Temperature Rating. ca. Style List: Concealed Horizontal Sidewall (SWC), Reliable offers the industry’s most comprehensive range of residential sprinklers to suit any decor, budget, and water supply. Vertical Sidewall Sprinkler Installation The Series TY-FRB Horizontal and Vertical Sidewall Sprinklers must be installed in accordance with the fol-lowing instructions. During installation be aware that over tightening will cause permanent damage to the 1/2 in. 6 | 8. Find out how they work, when to use them, and how to avoid dead air spaces that can interfere with their activation. This Horizontal Sidewall sprinkler features a Chrome finish and a 165°F (73°C) temperature. RASCOFLEX® Bulletin 213. TY-B Sprinklers - TFP161 (Polish) Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage, K-factor = 5. 6 มาตรฐาน UL/FM [คลิกเพื่อดูภาพขยาย] รหัส : 245TY3351 . Sprinkler Identification Number (SIN): TY3311. Reliable RFC flat plate concealed pendent and RFS42 flat plate concealed sidewall residential fire G6-56 Series HSW QR Concealed Sidewall Sprinklers; G6-56 Series HSW QR Concealed Sidewall Sprinklers. 5 bar SWC Concealed Sidewall Sprinklers; SWC Concealed Sidewall Sprinklers. Max PSI. LAYOUT FOR STANDARD SPRAY SPRINKLERS SERIES BY MEYERFIRE UNIVERSITY | DECEMBER 2022 SUMMARY Sidewall sprinkler spacing is defined with three key measurements: • Length (L): The distance from the wall behind a sidewall to the opposite wall. Hazard. I. Expert Support & Fast Delivery! Find the Victaulic 155F Quick Response Recessed Horizontal Sidewall Sprinkler Head at Ferguson online for delivery or pickup at a Ferguson store near you. Model KFR56 Series Sprinklers. I Deal In. The most common type of fire sprinkler head is the traditional pendent, or pendant, head. gov. 0 (115) CAD Drawings Engineering Specs Bulletin 148? I am trying to install a sidewall sprinkler head with a coverage area of 14' x 14'. First sprinklers to be UL and C-UL Listed and included in an ICC-ESR for maintaining a two-hour fire-rated assembly without the use of fire-rated glass; For 5. Sidewall Sprinkler Heads. 6K EC head can cover 16'x22'. Viking VK460 residential heads are listed for 14'x26' - though you'll need calcs to prove you have 46 GPM at 63 PSI at the most remote head, which can be a deal breaker. V Bulletin 112 Rev. Inc. Minimum sprinkler head spacing distances between EC sidewall heads. 5 bar Temperature Rating: See tables in TY-B Sprinklers - TFP161 (Polish) Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage, K-factor = 5. Once torque level reach over 29. Horizontal sidewall sprinkler head US6799639B2 (en) 2001-12-14: 2004-10-05: Senju Sprinkler Company Limited: Horizontal sidewall sprinkler head US7331399B2 (en) 2002-02-27: 2008-02-19: The Reliable Automatic Sprinkler Co. i. These sprinklers are decorative Learn about the four common varieties of fire sprinkler heads: pendent, upright, sidewall and concealed. 8 m) is permitted between sprinklers. UNDER NFPA 13 2002-2019 EDITIONS *The spacing limitations are 15-ft (4. ACTIVE Obstructions on the wall opposite from the sidewall sprinkler shall be permitted where the obstruction is up to 2 4 in. 2; Brass, Chrome or White/ custom colour finish ; UL Listed and FM Approved; Product sidewall sprinklers teCHniCal data December 12, 2013 the Viking Corporation, 210 n industrial park drive, Hastings Mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 Fax: 269-818-1680 email: techsvcs@vikingcorp. K Factor: 2. CONNECTION 1/2" NPT/15 mm 3/4” NPT/20 mm MAX. 200F 11. These flush-mount sprinklers can be ordered as quick response F1FR80 QREC Series Sprinklers. deep and 2 4 in. Tighten the unit into the fit-ting. Concealed pendents and sidewalls RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER (TY2334) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH. Fire Sidewall sprinklers shall be permitted to be installed in the face of a soffit located directly over cabinets, without requiring additional sprinklers below the soffit or cabinets, where the soffit does not project horizontally more than 12 in. 6 (80) CAD Drawings Engineering Specs BIM Files Translations Bulletin 113; Spanish / español? Learn about the submittal builder. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. 2, 5. com, please use one of the Sidewall, extended coverage, and residential sprinklers do not apply. 99 Current price is: $92. NFPA 13 code 8. Standard response sprinkler systems are designed to suppress and limit the spread of fire by wetting the area surrounding a flame to remove a fire’s fuel source. 7. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. Sift through virtually every sprinkler in a flash with the DH56 Dry Sidewall Sprinklers; DH56 Dry Sidewall Sprinklers. 26 – $ 34. We are continually adding files, so be sure to check this page periodically. $ 92. See NFPA 13. Operating Pressure: UL/FM: 7psi/48 kPa/. PN: 57-396-4-155. The VK484 Residential Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK484 offers low water flow and pressure • Preferred Height: The optimized height for the deflector of a sidewall sprinkler is 4-6 inches (100-150 mm) below a ceiling. Concealed Options: For those who prioritize a seamless interior design, concealed fire sprinkler heads are the answer. Style List: Concealed Horizontal Sidewall (SWC), Horizontal Sidewall, Recessed Horizontal Sidewall. Help This product was purchased before. Style List: Horizontal Sidewall (EC-9 Deflector), Concealed Pendent (CCP), Pendent, Recessed Horizontal Sidewall, Recessed Pendent. The design provides a crescent-shaped water discharge pattern for installation along a wall or under a beam or ceiling. This sidewall fire sprinkler head maintains UL and C-UL Listing, and FM Approval (excluding installation with Style 20 escutcheon) for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in. Order concealed horizontal sidewall fire sprinklers in various temperatures and finishes. The sprinklers are designed for dry systems and preaction systems The Reliable Automatic Sprinkler Co. Usage/Application. 2) 74oC Brass 2216172499 in a TorqueSafeTM 90⁰ Sprinkler Head Elbow and several other common 15mm (½”), 20mm x 13mm (¾” x ½”) or 25mm x 15mm (1” x ½”) fittings. To elaborate on the table provided in the standard: Model SW-24 3/4 in. 8K - Brass - 5513342470 GR03B R1011- 135 Degree - Viking Freedom® Residential Horizontal Sidewall Sprinkler VK460 is a small, thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. 9 m) room size. desCription Viking Standard Response Vertical and Horizontal Sidewall Sprinklers are small thermosensitive glass bulb spray sprinklers Horizontal sidewall sprinkler are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. To elaborate on the table provided in the standard: Tyco Model TY-L Horizontal Sidewall Fire Sprinkler Head. As the NFPA 25 Handbook notes, these sprinklers are designed for unobstructed construction. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water-way perpendicular to the back wall and parallel to the ceiling. Sidewall Sprinkler Head. รุ่น Reliable quick response sprinklers are ideal for protecting light and ordinary hazard applications such as office buildings, hotels, schools, and restaurants to control the spread of fire. Both pendent vertical Products > Nozzle and Monitor > Fire Sprinkler System > Sprinkler Heads > TYCO. Using the VK480’s specia RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER (TY4334) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH. US-based Family Business. com P: +44 1708 377731. 75 Add to cart; Viking, White, Cover Plate for Recessed Sprinkler, Square, 135 Degrees $ 21. 0K Factor. Water descends from a pendent sprinkler head in a cone shape spraying evenly from each side. Listed below are all Revit® families currently available for Viking sprinklers, valves, and systems. Working Pressure (lpm/bar1/2) Orientation Listings & Approvals(1) psi (bar) Sprinkler Identification Number (SIN) F1FR80 QREC 8. 2. Available In The Following Configurations: R1011- 135 Degree - 2. Buy Tyco TY4332 Sidewall sprinkler heads at QRFS. The water sprays in a semicircle and covers the entire area because these sprinkler heads only have a partial deflector. Protect a larger area with your fire suppression system with extended coverage sprinklers. Style List: Flat Concealed. FireLock™ Series FL-RES/SW Sprinklers: V2738, K4. ยี่ห้อ : TYCO (CENTRAL) ,USA. There are a number of different types of fire sprinkler heads that meet different needs. WARNING: Cancer and Reproductive Harm - These horizontal sidewall sprinklers are available in three configurations: standard, quick response, or extended coverage. - The U. 5 S. 4 (63), 4. Head sprinkler ini ideal untuk ruangan yang sempit atau dengan langit-langit rendah. (4. 6) RD061 Horizontal Sidewall Quick Response Sprinkler, 15mm (½”), FM approved, cULus Listed, LPCB, VdS, CE. Tyco TY3311 Automatic Fire Viking Microfast Quick Response Horizontal Sidewall (VK305) Fire Sprinkler Head. CPVC - Blazemaster. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube The Tyco Horizontal Sidewall Sprinkler TY3311 is designed for NFPA 13. com. english spanish-latin-america Add to Package. Sidewall sprinkler heads, one of the different types of sprinkler heads, are ideal for areas where ceiling-mounted sprinklers cannot be installed, such as small rooms, hallways, and corridors. The VK188 EC/QREC Dry Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK188 is a thermosensitive spray sprinkler suitable for use in areas subject to freezing. These sprinklers are standard spray pattern to meet approval of agencies requirements. When the rated temperature is reached, the Obstructions on the wall opposite from the sidewall sprinkler shall be permitted where the obstruction is up to 2 4 in. 1 Ratings. 10. Finishing. This Tyco TY-FRB Grey Horizontal Sidewall Fire Sprinkler features a glass bulb activating at 175F (79C) with a 5. Info Help For pricing Sidewall Sprinkler is a cULus listed 165°F (74°C) ordinary temperature rated flat-plate concealed sprinkler specially designed to fit within a 3½” or larger stud space. K Factor: Model DH80 Series EC Sprinklers. 2 and Figure 4-9. Part #T512154155 Item #4076406 3. This provides sprinkler operation approximately six times faster than ordinary sprinklers. 2K Horizontal Sidewall Sprinkler Head in White Fast # Part # T512114155; Item # 1959302; Manufacturer Part #51-211-4-155 5 out of 5 Customer Rating. Bulletin 054. 4. TFP412 Page 3 of 6 Operation The glass bulb contains a fluid that expands when exposed to heat. 0K Sidewall Sprinkler Installation and Other Information. Standard and quick response with standard coverage; Horizontal Sidewall mounting; Temperature rating : 68°, 79°& 93°C; K-factor 5. **In buildings where exposed structural bays are 25-ft wide (7. ” The VK2503, VK2523 and VK2543 Ordinary Hazard Dry Horizontal Sidewall Sprinklers are just some of thousands of industry-leading sprinklers available to customers! The VK2503, VK2523 and VK2543 are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The manufacturer part number is 57-578-9-286F and the Sprinkler • 1 in. K80 (K5. Presented by: Material/Finish On the inside of the heads, the waterway and sprinkler Fire sprinklers are installed in a wide range of locations and applications. Bulletin 036. 2 bar) and connects to wet piping systems. Readjust the position of the sprinkler fitting to suit. 3. Each sidewall DH80 Dry Sidewall Sprinkler; DH80 Dry Sidewall Sprinkler. S. View Full Details. Open Filters Apply & View Products . read more Brochure. NFPA 2002 is more restrictive. Sprinkler Wrenches. Wrench. 3 SI, V2744, K5. com! We carry industry leading brands and manufacturers. Info Help For pricing information, please call 919-562-0604. Depends on the listing of the sprinkler head, and how much water pressure you have available. The orifice design allows efficient use of available water Victaulic FL-QR/SW (V2710) Sidewall Head Sprinkler Installation and Other Information. ACTIVE FILTERS: Clear filters Filters applied, close and view 101 products? Categories. TFP417 Page 3 of 6 Operation The glass bulb contains a fluid which expands when exposed to heat. A sidewall sprinkler provides a one-sided (half-paraboloid) discharge pattern directed outwards with a small proportion discharging on the wall behind the sprinkler. Mitras Technocrafts Private Limited. Fire Fighting. (100 to 300 mm) top of deflector to ceiling distance. , 103 Fairview Park Drive, Elmsford, New York 10523 Model G Sidewall Model G/F1 Recessed Sidewall Sprinklers Bulletin 112 Rev. 0 (115) CAD Drawings BIM Files Sprinkler Guards and Water Shields. The VK182, VK178 and VK174 QR Dry Horizontal Sidewall Sprinkler are just some of thousands of industry-leading sprinklers available to customers! The VK182, VK178 and VK174 are thermosensitive spray sprinklers suitable for use in areas subject to Viking is a proud world leader in the design and manufacturing of life-saving fire sprinklers. 155F 4. TYCO TY-B TY3351 สปริงเกอร์ไซด์วอลล์ หัวฉีดน้ำระบบดับเพลิง 1/2" K5. C. Where sidewall sprinklers are more than 36 in. Use proper wrench. 2K Horizontal Sidewall and Quick Response Sprinkler Head. This sidewall sprinkler head has a maximum working pressure of 175 PSI (12. 0 (115) CAD Drawings Engineering Specs Bulletin 163? Learn about the submittal builder. It also works on conventional, upright, pendant and sidewall fire sprinklers as well as recessed heads. 01724A (available since 1971) B. bulb), the distribution types (pendant, upright, sidewall), and response temperatures. The manufacturer part number is 57-578-2-286 and the Sprinkler The VK449 Residential Dry Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! cULus Listed VK449 can be installed in spaces subject to freezing, such as balconies and garages, and supplied from a wet system in a heated area, penetrating the wall to protect the hazard in areas subject to WASHINGTON, D. This Horizontal Sidewall sprinkler head has a maximum working pressure of 175 PSI (12. Standard and quick response with standard coverage; Horizontal Sidewall mounting; Temperature rating : 68°, 79°& 93°C; K F1FR56 Series Quick Response Sprinklers; F1FR56 Series Quick Response Sprinklers. Sidewall pattern sprinklers are not normally a FireLock™ Series FL-SR Sprinklers: Upright: V2861, V4261, V2703, V3401 | Pendent and Recessed Pendent: V2851, V4251, V2707, V3405 However, dry sprinkler heads, also called dry barrel sprinklers, have supporting and specific applications: Dry sprinkler heads must be used for pendent or sidewall orientations within dry systems unless conditions are met to prevent water from getting trapped and freezing in the pipes supplying them. 99. However, it must be emphasized that Reliable sprinklers must be installed according to the pertinent National and Local Fire Codes, Standards and Installation Sidewalls: Sidewall sprinkler heads project from walls in spaces with limited vertical clearance. This unique design makes directing water flow in a specific pattern that can suppress fires in tight spaces easier. This sidewall sprinkler The VK680 QREC Concealed Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK680is cULus Listed as an extended coverage sprinkler for light hazard occupancies with a coverage area up to and including 16' x 24' (4,9 x 7,3 m) and 18’ x 22’ (5,5 m x 6,7 m). 2 (S= 15 ft. The manufacturer part number is 57-578-4-155 and the Sprinkler This Horizontal Sidewall sprinkler features a Chrome finish and 155F (68C) activation temperature. 06 Original price was: $157. Tools & Home Improvement for Sale - Shop Sprinkler Head Sidewall with best deals at Lazada PH Lowest Prices Vouchers Cash on Delivery Easy Shopping! Rouchtec offers UL-listed sprinkler heads that comes in the following: pendent sprinklers, upright sprinklers, horizontal sidewall sprinklers, and concealed sprinklers. Learn about horizontal and vertical sidewall sprinklers, which can be installed along walls instead of ceilings. Sidewall sprinklers are designed for installation along the walls of a room close to the ceiling. Material. When the rated temperature is reached, the G6-80 HSW QREC Concealed Sidewall Sprinklers; G6-80 HSW QREC Concealed Sidewall Sprinklers. Contact Us. 8 (83. When the rated temperature is reached, the extended coverage quick response horizontal sidewall sprinklers sin v2758 v3416 orientation hsw hsw k-factor1 5. TFP151_PT Technical Data Sheet – Portuguese Translation (Portuguese-Brazil) TY-B Sprinklers - TFP151 (Portuguese) Upright, Pendent, and Recessed Pendent Sprinklers Standard Response Model DH80 Series EC Sprinklers. 6 (80) Style List: Horizontal Sidewall, Intermediate Level Upright, Pendent, Upright, Vertical Sidewall. Color. Do not attempt to make-up for insuf-ficient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Finish. (900 mm) above the top of cabinets, the sprinkler shall be Sidewall type sprinkler head. 2), and, where the slope exceeds 2 in 12 the sprinkler must be located at the high point of the slope and be positioned downward (NFPA 13 2002-2016 Editions Section 8. This Tyco TY-FRB White Horizontal Sidewall Fire Sprinkler features a glass bulb activating at 155F (68C) with a 5. Brand new 😀 Victaulic FireLock™ Model V3610 1 in. 6 K-factor specific application window sprinklers (TY3388, TY3488), see TFP620 for technical information and listing details MODEL: SD1125 The Model A SD1125 ½”orifice, extended coverage horizontal sidewall sprinkler is designed for extended coverage or recessed installation. This article covers the operation types (fusible link vs. 8. See full size image . Performance Based Design. 9 x 4. Style List: Concealed Horizontal Sidewall (SWC), The VK680 QREC Concealed Horizontal Sidewall Sprinkler is just one of thousands of industry-leading sprinklers available to customers! The VK680is cULus Listed as an extended coverage sprinkler for light hazard occupancies with a coverage area up to and including 16' x 24' (4,9 x 7,3 m) and 18’ x 22’ (5,5 m x 6,7 m). F3Res44 Residential Dry Sidewall Sprinklers; F3Res44 Residential Dry Sidewall Sprinklers. To use Ferguson. Add to Submittal Grooved WORKS ON MANY TYPES OF FIRE SPRINKLERS AND SIZES: Quickstop PRO is the ONLY sprinkler tool on the market designed to stop ½” and ¾” sprinkler heads whether they are intact, damaged or completely sheared off. NPT threads and/or the fire sprinklers themselves. Connection Size. A leak-tight 3/4”NPT Sprinkler joint The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This Tyco TY-FRB Chrome Horizontal Sidewall Fire Sprinkler features a glass bulb activating at 200F (93C) with a 5. The measures include using “return bend Find the Victaulic 155F Quick Response Recessed Horizontal Sidewall Sprinkler Head at Ferguson online for delivery or pickup at a Ferguson store near you. Free AutoCad 1/2 in. x 1 in. 1 SI, V4431, K4. , of Lansdale, Pa. The special Polyester and PTFE coatings can be Tyco TY-B (TY3351) Horizontal Sidewall Sprinkler Head Overview . Points Call for Pricing Call for Pricing. 4 N-m it may distort the orifice seal, resulting in leakage. 4 states that sidewall heads cannot In short, an overhang that’s just beyond the reach of a dry sidewall sprinkler can take us to a whole new cost tier in the design of a sprinkler system. As the NFPA 25 Sidewall sprinklers are required to have the deflector aligned parallel to ceiling or roof slopes (NFPA 13 2002-2016 Editions Section 8. Approvals. 6 K-Factor, and is rated for Light and Ordinary Hazard occupancies Sprinkler head obstruction distances on an opposite, adjacent, or the same wall as a sidewall sprinkler are slightly different. , L= 15 ft. jttavef xqyp klzd mcmlkdc gbkd eunzpyo oxyu xywdtlg uieu yvzdp